Likewise, the status of external devices is transmitted to the master station link devices (RX, RWr) via the slave station. *16: Number of link points allocated by the master station. When an input from a slave or local station is executed, the slave station link devices (RX, RWr) status and local station link devices (RY, RWw) status are stored in the master station link device (RX, RWr), along with other local station link devices (RY, RWw). ② In the master station, the status of the CPU module devices are stored in the link devices (RY, RWw) by link ② In the transmitting station, the CPU module devices status are stored in the link devices (LB, LW) of the CC-Link IE Control Network supporting module by link refresh. The status of link devices (RY, RWw) within the master station are transmitted to an external device connected to a slave station. Remote output RY: Bit data output from the master station to a slave station CC-Link IE Field Network Basic is an factory automation network using the standard Ethernet. USB (Mini-B) connector SD memory card slot Ethernet port Under CC-Link IE Field and Control networks, some differences exist as described in this section. CC-Link IE Field Network *25 One-to-one communication is possible between the master and slave stations. Up to 20 hubs can be connected. Motion control Specification: Part 1. ⑤ In the local station, devices of the CPU module turn ON. CC-Link IE field network Basic is also supported. iQ-R Series, RD78G4/RD78G8/RD78G16/RD78G32/RD78G64/RD78GHV/RD78GHW, Motion Module, GX Works3, CC-Link IE Field Network Basic master module and the CC-Link IE Field Network Basic servo amplifier MR-JE-C, MotionControl_RD77 library for iQ-R Series Simple Motion Module, GX Works3, CC-Link IE Field Network master module and the CC-Link IE Field Network servo amplifier MR-J4-GF, iQ-R Series RD77MS2/RD77MS4/RD77MS8/RD77MS16 Simple Motion Module, GX Works3, iQ-F Series FX5-40SSC-S Simple Motion Module, GX Works3, Q Series QD77MS2/QD77MS4/QD77MS16 Simple Motion Module, GX Works2, L Series LD77MS2/LD77MS4/LD77MS16 Simple Motion Module, GX Works2, L Series LD77MH16 Simple Motion Module, GX Works2, L Serie LD77MH4 simple motion module, GX Works2. IEC 60793-2-10 Types A1a.1 (50/125 µm multimode), Category 5e or higher, (STP) straight cable. Cables that conform to the following standards. Likewise, the status of the normal station link devices (LB, LW) is stored in link devices (LB, LW) of the control and other normal stations. This website or its third-party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. ⑥ In the local station, the status of the CPU module devices are stored in its own station link devices (RY, RWw) transmission area. CC-Link IE Field Network performance specifications, CC-Link IE Control Network performance specifications, CC-Link IE Field Network Basic performance specifications, 121 stations (1 master station. This lets you construct a network with general-purpose Ethernet. *9: 16384 points and 2K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU. *4: Number of link points allocated by the master station. Link input LX: Data input from a station to the I/O master in the same block. *1: A hub is required to use the star type wiring. ① In the master station, devices of the CPU module turn ON. We offer a comprehensive line of factory automation solutions. *: May partially differ for local stations. An I/O master station, which controls link inputs (LX) and link outputs (LY), and another station make one to one communication. CC-Link IE Field Network Basic compatible twisted-pair cable. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the, Cpu module function block reference (44 pages), Analog control - intelligent function module (496 pages), Melsec iq-f series, ethernet communication (178 pages), Instructions, standard functions/function blocks (1112 pages), Manual will be automatically added to "My Manuals", Controller Mitsubishi Electric FX5U User Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5U User Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5 Reference Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5 User Manual, Controller Mitsubishi Electric FX5 User Manual, Controller Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual, Controller Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual, Page 22: Chapter 3 Procedures Before Operation, Page 71: Details Of Buffer Memory Addresses. … This function allows each station to write data to its own send range of a link device (LB, LW) to send them to all other stations on the network. The control or normal station can be an I/O master station, and up to two I/O master stations (block 1 and block 2) can be used per network. Communications using link relays (LB) and link registers (LW). *7: Line and star types can also be mixed. Note that communication is made between the master station and the slave stations only. For details on cyclic transmission, refer to the following. Link output LY: Data output from the I/O master station to another station in the same block. LX is the input data transmitted between stations in a block, and LY is the output data transmitted from the I/O master station in a block. Remote register RWw: 16-bit (word) unit data output from the master station to a slave station. The status of link devices (RY, RWw) within the master station are transmitted to an external device connected to a slave station. ③ The status of the master station link devices (RY, RWw) are then stored in the slave station link devices (RY, RWw), and in the local station link devices (RX, RWr) by link scan. For detailed information about performance specifications, please refer to the “CC-Link IE Field Network Basic Reference Manual (SH(NA)-081684ENG)”. In the case of local stations, the status of the master station link devices (RY, RWw) is relayed to all local station link devices (RX, RWr) on the network. *25: The data is transmitted in the same method on CC-Link IE Field Network Basic. Transmissions using link inputs (LX) and link outputs (LY). 120 slave stations), Ethernet cable (Category 5e or higher, double shielded/STP), straight cable, Line type: 12,000 m (When 1 master station and 120 slave stations are connected), 120 (1 control station, 119 normal stations), Ethernet standard compatible cable, Category 5e or higher (STP cable), 64 points; up to 256 points can be allocated according to the number of stations, 32 points; up to 128 points can be allocated according to the number of stations, Ethernet cable (Multi-mode optical fiber), Ethernet cable (Category 5e or higher, double shielded/STP), Twisted pair cable (CC-Link dedicated cable), Category 5e or higher, (double shielded/STP) straight cable. ③ The status of the link devices (LB, LW) in the transmitting station are sent to the link devices (LB, LW) of the CC-Link IE Control Network supporting module in the receiving station by link scan. CC-Link IE Field Network Basic CC-Link IE Field Network Basic is an factory automation network using … Remote register RWw: 16-bit (word) unit data output from the master station to a slave station *5: Under CC-Link IE Control Network, the number of connectable normal stations per network differs by the CPU module used in the control station. CC-Link IE Field Network Basic master module and the CC-Link IE Field Network Basic servo amplifier MR-JE-C. Motion control Specification: Part 1. refresh. ① In the transmitting station, the CPU module devices turn ON. *23: For recommended cables and other information, contact the CC-Link Partner Association. Compliance statement Statement ... FX5U, MR-JE-A via Modbus, GX Works3. *17: Value when the extended mode is used. *8: Link relay LB: Bit data transmitted from stations in the network. One-to-one communication is possible between the master and slave stations. As a result, all local stations possess the data of other slave stations, similar to the master station. *2: Line and star types can also be mixed. The total number of allocated stations should not exceed the maximum number of slave stations. Data is periodically communicated between the master station and slave stations using link devices (cyclic transmission). *10: 16384 points and 32K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU. *15: Remote input RX: Bit data input from a slave station to the master station CC-Link IE Field Network Basic does not require setting of the connection with the slave station. OUTLINE FX5-ENET Ethernet module (hereinafter referred to as FX5-ENET) is an intelligent function module for connecting to a CC- Link IE Field network Basic and general-purpose Ethernet. *12: Maximum number of slave stations controlled by the master station, depending on the number of allocated slave stations. CC-Link IE compatible twisted-pair cable*23. For further details, please refer to the relevant product manuals. Remote register RWr: 16-bit (word) unit data output from the master station to a slave station The status data of the control station link devices (LB, LW) are stored in the link devices (LB, LW) of each normal station. In cyclic transmission, data is transmitted periodically using link devices. *3: Remote input RX: Bit data input from a slave station to the master station No local stations are available on the CC-Link IE Field Basic. A local station can also use other link points to receive data from other stations. (1) Configure the entire network of CC-Link IE Field Network Basic in the master station. This function allows communications with other stations when a request is made by a method such as a dedicated instruction and engineering tool. Communications with different networks is also possible. Page 22 Cyclic Transmission RX, RWr RX, RWr RX, RWr Remote register RWr: 16-bit (word) unit data output from the master station to a slave station ⑧ The status of the master station link devices (RX, RWr) are stored in the CPU module devices by link refresh. *22: Value of remote register RWr + RWw (word). Link register LW: 16-bit (word) unit data transmitted from stations in the network. *11: To use the extended mode, all the stations must be compatible with the extended mode. *24: CC-Link IE Field Network Basic supports star topology only. *14: The maximum distance between stations depends on the actual hub used.